Product Identification
Product ID:NICKEL CADMIUM SEALED CELL BATTERY
MSDS Date:10/03/1994
FSC:6140
NIIN:01-123-8894
MSDS Number: BYHJX
Responsible Party
VALDOSTA, GA 31603
US
Emergency Phone: 800-424-9300
Info Phone: 912-245-2880
Cage: 09052
Contractor
Telephone: 912-247-2331
Cage: 09052
Ingredients
CADMIUM (SARA 313) (CERCLA)
CAS: 7440-43-9
RTECS: EU9800000
Fraction By Weight: <17%
OSHA PEL 0.2 MG/M3 DUST; Z-2
ACGIH TLV: 0.01 MG/M3 DUST;9495
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
CADMIUM HYDROXIDE
CAS: 21041-95-2
Fraction By Weight: <17%
OSHA PEL 0.05 MG CD/M3
ACGIH TLV: 0.05 MG CD/M3
CADMIUM OXIDE (SARA 302/313) (CERCLA)
CAS: 1306-19-0
RTECS: EV1925000
Fraction By Weight: <17%
OSHA PEL 0.2 MG (CD)/M3 DUST
ACGIH TLV: 0.01 MG(CD)/M3; 9495
NICKEL (SARA 313) (CERCLA)
CAS: 7440-02-0
RTECS: QR5950000
Fraction By Weight: <19%
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3; 9495
NICKEL HYDROXIDE (SARA 313) (CERCLA)
CAS: 12054-48-7
RTECS: QR7040000
Fraction By Weight: <19%
OSHA PEL 1 MG(NI)/M3
ACGIH TLV: 0.1 MG(NI)/M3; 9495
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
NICKEL OXIDE
CAS: 1313-99-1
RTECS: QR8400000
Fraction By Weight: <19%
OSHA PEL 1 MG/M3 AS NI
ACGIH TLV: 1 MG/M3 AS NI
POTASSIUM HYDROXIDE (CERCLA)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 8%
OSHA PEL C 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9495
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
COBALT (SARA 313)
CAS: 7440-48-4
RTECS: GF8750000
Fraction By Weight: 1%
OSHA PEL 0.1 MG/M3
ACGIH TLV: 0.02 MG/M3; A3; 9495
Hazards
LD50 LC50 Mixture:NOT GIVEN FOR PRODUCT AS A WHOLE
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ELECTROLYTE IS EXTREMELY CORROSIVE TO
TISSUES. MAY RESULT IN PERMANENT BLINDNESS. MAY CAUSE SERIOUS BURNS
TO SKIN TISSUE. INGESTION MAY CAUSE TISSUE DAMAGE TO THROAT AREA
AND GI TRACT. INHALATION OF C ADMIUM AND/OR NICKEL FUMES MAY CAUSE
DRY THROAT, COUGH, HEADACHE, VOMITING, CHEST PAIN, CHILLS.
Explanation of Carcinogenicity:BATTERY IS SEALED CELL. NISOH RECOMMENDS
THAT NICKEL AND CADMIUM BE TREATED AS OCCUPATIONAL CARCINOGENS IF
CELL DAMAGED.
Effects of Overexposure:EYE BURNS, BLINDNESS, TISSUE DAMAGE, SKIN
BURNS, GI TRACT DAMAGE, DRY THROAT, COUGH, HEADACHE, VOMITING,
CHEST PAINS, CHILLS, PULMONARY EDEMA, BREATHING DIFFICULTY,
PROSTRATION, KIDNEY DAMAGE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: FLUSH WITH WATER FOR 15 MINUTES WHILE HOLDING EYELIDS
OPEN. GET MEDICAL ATTENTION. SKIN: REMOVE CONTAMINATED CLOTHING.
WASH WITH SOAP AND WATER. IF IRRITATION PERSIST, GET MEDICAL
ATTENTION. INH ALATION: REMOVE TO FRESH AIR. RESTORE BREATHING. GET
MEDICAL ATTENTION. INGESTION: DO NOT INDUCE VOMITING. DILUTE WITH
WATER OR MILK. GET MEDICAL ATTENTION.
Fire Fighting
Flash Point:NONFLAMMABLE
Extinguishing Media:CARBON DIOXIDE, SAND.
Fire Fighting Procedures:USE SELF-CONTAINED BREATHING APPARATUS TO
AVOID BREATING TOXIC FUMES. WEAR PROTECTIVE CLOTHING AND EQUIPMENT
TO PREVENT POTENTIAL BODY CONTACT WITH ELECTROLYTE.
Unusual Fire/Explosion Hazard:CADMIUM FUMES MAY BE RELEASED WHEN
BATTERIES ARE SUBJECTED TO HIGH TEMPERATURES. IN CASE OF FIRE, DO
NOT BREATHE SMOKE AND FUMES.
Accidental Release
Spill Release Procedures:ELECTROLYTE SPILLS: FLUSH WITH WATER AND
NEUTRALIZE WITH DILUTE CITRIC ACID.
Neutralizing Agent:CITRIC ACID.
Handling
Handling and Storage Precautions:THESE CELLS AND THE BATTERIES
CONSTRUCTED FROM THEM MAY BE HIGHLY CHARGED AND ARE CAPABLE OF HIGH
ENERGY DISCHARGE. DO NOT SHORT CIRCUIT.
Other Precautions:CARE SHOULD BE TAKEN TO HANDLE CELLS PROPERLY TO
AVOID SHORTING OR MISUSE THAT WILL RESULT IN RAPID UNCONTROLLED
ELECTRICAL, CHEMICAL OR HEAT ENERGY RELEASE. DO NOT BREA OPEN CELL.
DO NOT ALLOW AN EXP OSED FLAME OR SPARK TO COME NEAR THE CEL
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIARATOR IF CELL
BROKEN OPEN DURING FIRE TO MAINTAIN EXPOSURE LEVELS BELWO TWA FOR
CADMIUM AND NICKEL COMPOUNDS.
Ventilation:LOCAL EXHAUST AND MECHANICAL (GENERAL) VENTILATION AS
REQUIRED TO MAINTAIN EXPOSURE LEVELS.
Protective Gloves:SYNTHETIC RUBBER--NOT LEATHER OR WOOL.
Eye Protection:SPLASH GOGGLES OR FACE SHIELD
Other Protective Equipment:RUBBER APRON OR EQUIVALENT IF EXPOSURE TO
ELECTROLYTE IS LIKELY.
Work Hygienic Practices:WASH HANDS THOROUGHLY WITH SOAP AND WATER
BEFORE EATING, DRINKING, SMOKING OR USING TOILET FACILITIES.
Supplemental Safety and Health
Chemical Properties
HCC:N1
Spec Gravity:1.170-1.250
Solubility in Water:ELECTROLYTE-COMPLETE
Appearance and Odor:SEALED CELL NICKEL-CADMIUM BATTERY; 9.6 VOLTS; 1 YR
SHELF LIFE.
Stability
Stability Indicator/Materials to Avoid:YES
ORGANIC CHEMICALS, ESPECIALLY NITROCARBONS AND CHLOROCARBONS. ALSO
ZINC, ALUMINUM, TIN, OTHER ACTIVE MATERIALS.
Stability Condition to Avoid:PHYSICAL DAMAGE, SHORT CIRCUITING.
Hazardous Decomposition Products:HYDROGEN GAS, CADMIUM FUMES, NICKEL
OXIDE, CADMIUM OXIDE, POTASSIUM HYDROXIDE.
Disposal
Waste Disposal Methods:THE STORAGE BATTERY IS A HAZARDOUS WASTE UNDER
RCRA. IT MAY BE RETURNED TO SAFT FOR RECYCLING. BATTERY IS TCLP
TOXIC. BATTERY AND ELECTROLYTE SOLUTION ARE CORROSIVE. IF NOT
RECYCLED, MUST BE DISPOSED OF IN ACCORDANCE WITH ALL FEDERAL,
STATE LAWS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.